Providing Robust Support For 3 - Axis Magnetic Flux Density Measurement MAGNETING FIELD hiTESTER FT3470-52 HIOKI
Features
- Complies with ICNIRP 2010 guidelines as well as other relevant standards for evaluation testing.
- Complies with IEC 62110/ IEEE 644 and IEC 62233.
- Bundled with 3 cm2 sensor used for magnetic field distribution analysis, and 100 cm2 sensor required for IEC/ EN 62233 standard analysis
- User-selectable display units ( T, A/ m, and G)
- Simple operation for easy measurement
- Bundled with PC application software
- Level output for RMS value, or 3-axis waveform output for magnetic fields
Specifications :
- Magnetic flux density ( Bandwidth) : 10 Hz to 400 kHz/ 10 Hz to 2 kHz/ 2 kHz to 400 kHz
- Exposure level : General Public/ Occupational
- Display : Single axes X, Y, Z ( 2000 counts) , Composite RMS value R ( 3464 counts) , Magnetic flux density ( unit: T, G, A/ m) , Exposure level ( unit: % )
- Magnetic flux density/ Ranges and accuracy : [ X, Y, Z axes] Effective measuring ranges: 2.000 ¼ T to 2.000 mT, 4 ranges, Accuracy: ± 3.5% rdg. ± 0.5% f.s. [ R axis] Effective measuring ranges: 3.464 ¼ T to 3.464 mT, 4 ranges, Accuracy: ± 3.5% rdg. ± 0.5% f.s. [ Valid measurement frequency range] at 10 Hz-400 kHz mode: 50 Hz to 100 kHz at 10 Hz-2 kHz mode: 50 Hz to 1 kHz at 2 kHz-400 kHz mode: 5 kHz to 100 kHz
- Exposure level/ Ranges and accuracy : [ X, Y, Z axes] Effective measuring ranges: 20.00 % to 200.0 % , 2 ranges [ R axis] Effective measuring ranges: 34.64 % to 346.4 % , 2 ranges, Accuracy: Smoothed edges 50 Hz to 1 kHz ± 3.5% rdg. ± 0.5% f.s. Accuracy: Smoothed edges 1 kHz to 100 kHz ± 5.0% rdg. ± 0.5% f.s.
- Interfaces: [ Supporting output] Resultant RMS level output, Exposure level output, Waveform output of magnetic flux density X/ Y/ Z each axis, Output rate: 0.1 mV/ display value count [ USB 1.1] Data saving with the PC application
- Other functions : Memory function: Up to 99 measured value data, Slow function, Holds the maximum value, Auto power off, Buzzer sound on/ off
- Power supply : LR6 ( AA) alkaline battery × 4, 0.8 VA ( at battery operation) , Continuous use of 10 hr, or AC adapter 9445-02 ( 1.0 VA max. consumption)
- Dimensions and mass : Main unit: 100 mm ( 3.94 in) W × 150 mm ( 5.91 in) H × 42 mm ( 1.65 in) D, 830 g ( 29.3 oz) , ( including batteries) 100 cm2 Sensor: Æ 122 mm ( 4.80 in) × 295 mm ( 11.61 in) L, 220 g ( 7.8 oz) 3 cm2 Sensor: ¡ 27 mm ( 1.06 in) × 165 mm ( 6.50 in) L, 95g ( 3.4 oz)
- Accessories : 100 cm2 Sensor × 1, 3 cm2 Sensor × 1, Instruction manual × 1, CD-R ( PC application software Data Viewer for FT3470) × 1, USB cable × 1, LR6 ( AA) alkaline battery × 4, AC Adapter ( 9445-02 or 9445-03 for EU) × 1, Extension Cable 9758 × 1, Output Cable 9759 × 1, Carrying case × 1
SEGERA HUBUNGI KAMI HARGA DAN BARANG TIDAK TERIKAT
CV Hansa Indo Perkasa
Ruko surya Inti Permata Blok D57-58 Lantai II
Jl.Jemur Andayani No.50 Surabaya 60293
Telp : 031- 9901 3107
Fax : 031 - 9901 3107
Phone: 0822 9991 1749
Pin BB :5A6A5B8B